HYDESIGN
HYDRAULIC DESIGN ENGINEERING SUITE
RESERVOIR
PUMP
DCV
ACTUATOR
WAITConnecting to M1 Server...
READYCalculation engine online
MISHAL PATTANAYAKHYDRAULIC CALCULATION SUITE
ENGINEERING WORKBENCH β†—
WAITConnecting to M1 Server...
READYCalculation engine online
INTERACTIVE ENGINEERING DESK

Live Design Check

Change any value β€” key hydraulic parameters update instantly.

LIVE CALC
HYDRAULIC WORKFLOW

System Flow

Select a component to jump to its engineering module.

INTERACTIVE
β†’ β†’ β†’ β†’

Live Engineering Snapshot

Select any module and change values to see instant results.

LIVE

Quick Calculators

Jump directly to a module.

Engineering Status

Current dashboard checks.

Formula EngineACTIVE
SI / Metric UnitsENABLED
Calculation History0 SAVED
Website Analyticsβ€” VISITS
HYDRAULIC AI

Hydraulic AI Assistant

Ask about troubleshooting, calculations, commissioning, pumps, valves, cylinders, piping, HPU design or any hydraulic issue.

AI ENGINE
HYDRAULIC AITell me the hydraulic problem, symptoms, readings or calculation you need help with.
REFERENCE SELECTOR

Valve Selection

Select a valve family using required pressure, flow, size, actuation and application conditions. Limits shown are from the uploaded technical datasheets.

Selection Results

Enter your duty requirements and run the selector.

DATASHEET BASED
No selection made yet.

Valve Family Reference

Select a valve family to view its reference data.

REFERENCE
Select a valve family.

Cylinder Calculator

Blank project input sheet. Enter your actual cylinder data.

ISO Cylinder Match

Matches the entered bore and rod against the supplied Bosch Rexroth mill-type cylinder catalogues: CDM1 (RE 17329), CDL2 (RE 17327) and CDH1 (RE 17332). Standard bore/rod combinations and nominal pressure class are used for the selection check; mounting, buckling, cushioning, seals and actual configuration must still be verified.

Rexroth Seriesβ€”
Required Boreβ€”mm
Required Rodβ€”mm
Catalogue Bore / Rodβ€”mm / mm
Pressure Ratingβ€”
Selectionβ€”
MATCH SUGGESTIONEnter bore, rod and pressure to get a Rexroth catalogue match suggestion.

Results

β€”Run calculation to validate inputs and results.
Extension Force / Cylinderβ€”kNβ€” ton
Retraction Force / Cylinderβ€”kNβ€” ton
Extension Speedβ€”mm/s
Retraction Speedβ€”mm/s
Extension Flow / Cylinderβ€”L/min
Retraction Flow / Cylinderβ€”L/min
Combined Extension Flowβ€”L/min
Extension Volumeβ€”L/cylinder
Retraction Volumeβ€”L/cylinder

Cylinder Speed & Flow Calculator

Calculate cylinder speed from flow, or required flow from stroke and time.

Speed & Flow Results

β€”Run calculation to validate inputs and results.
Extension Speedβ€”mm/s
Retraction Speedβ€”mm/s
Extension Flow Requiredβ€”L/min
Retraction Flow Requiredβ€”L/min
Extension Stroke Timeβ€”s
Retraction Stroke Timeβ€”s

Piping Calculator

Based on the supplied Rexroth/Mannesmann piping calculation workbook.

Enter flow to get an automatic OD Γ— wall suggestion.

Pipe Results

ID = 4.61 Γ— √(Q / V)Q = flow in L/min β€’ V = target velocity in m/s β€’ ID = required internal diameter in mm
β€”Run calculation to validate velocity and pipe selection.
Required Internal Γ˜β€”mm
Actual Internal Γ˜β€”mm
Actual Velocityβ€”m/s
Reynolds Numberβ€”Re
Flow Regimeβ€”
Laminar Factorβ€”Ξ»
Turbulent Factorβ€”Ξ»
Pressure Lossβ€”bar
Critical Velocityβ€”m/s
Recommended Pipeβ€”standard size

Recommended Pipe Sizes

The selector chooses the smallest listed internal diameter that meets the target velocity. Pressure rating and material must be verified against the selected tube or pipe standard.

Run the piping calculation to generate a recommendation.

Velocity Reference

Suction≀ 1.5m/s reference
Open-loop delivery≀ 3.5m/s reference
Closed-loop delivery≀ 7.0m/s reference
Return≀ 3.0m/s reference

Application reference values used by HYDESIGN; verify final sizing against project and component limits.

Flow Regime Reference

Re < 2,000LaminarSmooth, orderly flow
2,320 – 4,000TransitionalUnstable flow
4,000 – 100,000TurbulentFriction affected by Re
Re > 100,000Highly TurbulentRoughness becomes significant
ENGINEERING CALCULATOR

Pump & Power

Three focused tools for pump flow, motor power and displacement sizing.

01 β€’ FLOW

Flow Calculator

β€”L/min
02 β€’ POWER RATING

Motor Power Calculator

β€”kW required
03 β€’ PUMP DISPLACEMENT

CC Calculator

β€”cc/rev required
PUMP REFERENCE SELECTOR

Pump Family Selection

Filter catalogue data by circuit, required pressure and required flow.

REFERENCE
Enter duty requirements and run the selector.
No selection made yet.

Pump Family Reference

Select a family to view catalogue range, pressure level, sizes and controls.

REFERENCE
Select a pump family.
COMPONENT CONVERSION & RETROFIT SUPPORT

Hydraulic Component Cross-Reference

Enter another manufacturer's pump or valve model code. HYDESIGN will return preliminary Bosch Rexroth family candidates and compare known specifications side by side. A family suggestion is not an approved drop-in replacement.

Rexroth Make in India Reference (2025)

Search representative material numbers and product families from the uploaded Bosch Rexroth India reference. This quick index is not the complete ordering list.

SOURCE INDEX
Type a part number or product family to search the 2025 reference index.
No Rexroth reference selected for this comparison.
READYEnter the model code and any available technical data.

For best accuracy, attach or copy the original manufacturer's datasheet values. Exact ordering codes depend on configuration and must be confirmed by Bosch Rexroth documentation.

Side-by-Side Comparison

Existing component vs. proposed Bosch Rexroth candidate.

PRELIMINARY
Enter an existing model code and select COMPARE & FIND REXROTH MATCH to start.

Official Bosch Rexroth verification

Check released model codes, current datasheets, spare parts and product availability before ordering.

Open Bosch Rexroth Interactive Catalog System β†—

Open Bosch Rexroth India product / spare-part search β†—

4–20 mA Scaling

β€”Run scaling calculation to validate the signal.
β€”bar

Tank Calculator

β€”Run tank calculation to validate dimensions and fill factor.
β€”L useful volume

Unit Converter

β€”Run conversion to validate the input.
β€”

Engineering Information & Formulas

Reference information used by this calculation suite.

Hydraulic Cylinder

Piston area: Ο€DΒ²/4

Annular area: Ο€(DΒ²βˆ’dΒ²)/4

Extension force: Pressure Γ— piston area

Retraction force: Pressure Γ— annular area

Flow: Area Γ— stroke / time

Force: bar Γ— cmΒ² / 100 = kN

Tonnes: kN / 9.80665

Speed & Flow

Speed = Stroke / time

Flow = Area Γ— speed Γ— 60

Extension uses full piston area; retraction uses rod-side annular area.

Pump & Power

Flow = displacement Γ— RPM Γ— volumetric efficiency / 1000

Hydraulic power β‰ˆ Pressure Γ— Flow / 600

Motor sizing should include applicable efficiency and service margin.

Piping

Suction reference: 1.5 m/s

Open-loop delivery: 3.5 m/s

Closed-loop delivery: 7 m/s

Return: 3 m/s

Reynolds number and friction-factor checks are included.

4–20 mA

Output = Range Γ— (mA βˆ’ 4) / 16

Use the configured transmitter range for the maximum value.

Tank

Useful volume = L Γ— W Γ— H Γ— fill factor.

Dimensions are entered in mm and volume is reported in litres.

Engineering Notes

Results are theoretical calculations and should be checked against the actual machine, component datasheets, applicable standards, pressure ratings, temperature, oil properties, duty cycle and safety requirements before implementation.

Engineering Information & Formulas

Reference information used by this calculation suite.

Hydraulic Cylinder

Piston area: Ο€DΒ²/4

Annular area: Ο€(DΒ²βˆ’dΒ²)/4

Extension force: Pressure Γ— piston area

Retraction force: Pressure Γ— annular area

Flow: Area Γ— stroke / time

Force: bar Γ— cmΒ² / 100 = kN

Tonnes: kN / 9.80665

Speed & Flow

Speed = Stroke / time

Flow = Area Γ— speed Γ— 60

Extension uses full piston area; retraction uses rod-side annular area.

Pump & Power

Flow = displacement Γ— RPM Γ— volumetric efficiency / 1000

Hydraulic power β‰ˆ Pressure Γ— Flow / 600

Motor sizing should include applicable efficiency and service margin.

Piping

Suction reference: 1.5 m/s

Open-loop delivery: 3.5 m/s

Closed-loop delivery: 7 m/s

Return: 3 m/s

Reynolds number and friction-factor checks are included.

4–20 mA

Output = Range Γ— (mA βˆ’ 4) / 16

Use the configured transmitter range for the maximum value.

Tank

Useful volume = L Γ— W Γ— H Γ— fill factor.

Dimensions are entered in mm and volume is reported in litres.

Engineering Notes

Results are theoretical calculations and should be checked against the actual machine, component datasheets, applicable standards, pressure ratings, temperature, oil properties, duty cycle and safety requirements before implementation.

Website Statistics

Anonymous visit counter for this calculator.

Total Visitsβ€”visits
Your Browser Visitsβ€”visits
HYDRAULIC CHATBOT

Hydraulic Engineering Assistant

Ask any hydraulic-related question β€” troubleshooting, cylinder sizing, pump and motor selection, valves, HPU design, piping, pressure, flow, commissioning, calculations and component selection.

GEMINI AI
HYDRAULIC AIHello. I’m your hydraulic engineering assistant. Describe the machine issue, provide your pressure/flow/cylinder/pump/valve data, or ask for a calculation.
LIVE MARKET DATA

Live Stock Market Dashboard

Free community market feed β€’ watchlist, price change, high/low and volume

Ready to load market data.
SymbolLast PriceChangeChange %HighLowVolume
Press Refresh to load data.

Community-maintained feed; may be cached, delayed, unavailable or inaccurate. Not for trading decisions. Real-time streaming/options chain require licensed data.

Official NSE option chain for indices and stocks, including available strike-wise call/put prices, OI, volume, IV and bid/ask details.

MONEYCONTROL

Open full live option chain β†—

Embedded NSE viewIf NSE allows the page to load here, use the table below. If it is blocked by NSE security or browser restrictions, open the official page above.
β†—

Moneycontrol opens in a separate tab

Moneycontrol restricts copying, scraping and redistribution without written authorization. Open the official Moneycontrol market pages directly to view their live data and tools.

OPEN MONEYCONTROL MARKET β†— β†—

Moneycontrol live pages open directly in a separate tab. Native data display requires written authorization or an approved data feed.

Calculation History

Your saved calculations stay in this browser.

Built on Hatchable